OG Cells
Medium-voltage distribution panels
Safe Switching at Medium Voltage
OG cells are modular cell systems that switch on and off, measure, protect, and distribute medium-voltage power. We design and commission input, output, coupling, metering, and transformer protection cells, along with transfer and synchronization panels.
- Cell systems with circuit breakers and load breakers
- Transformer and Feeder Protection Cells
- Digital protection relays and selectivity
- Transfer and generator synchronization systems
Compliant with IEC 62271
Uninterrupted power, safe maneuvering
In medium-voltage switchgear, short-circuit withstand capacity, interlock safety, and protection coordination must never be overlooked.
We select OG cells in accordance with the relevant IEC 62271 standards, determine the settings of the protective relays through selectivity testing, and perform a controlled energization after verifying them with secondary injection tests.
1997
Since [year]
Our founders’ engineering experience, which began in 1997; since 2007, we have been manufacturing low-voltage and medium-voltage switchgear and undertaking turnkey contracting projects under the EGES Engineering umbrella.
27.000+
panel manufacturing
The panels, designed and tested in accordance with IEC 61439 at our own factory in Sancaktepe, include more than 3,500 units manufactured on a contract basis for global brands.
ISO
9001 · 14001 · 45001
Production, assembly, and field processes certified under quality, environmental, and occupational health and safety management systems.
What We Offer
Our OG Cell and Transfer Solutions
We offer medium-voltage distribution panels and transfer and synchronization systems for applications ranging from substations to power plant switchyards.
Input and output cells
Cells with circuit breakers or load breakers for grid feeders and feeder outputs.
Coupling cells
Flexible operation and backup capabilities across BARA sections.
Transformer protection cells
Transformer protection solutions with fused or circuit-breaker-protected load breakers.
Sensor cells
Measurement and meter connections using current and voltage transformers.
Transfer systems
Automatic transfer panels between the utility grid and the generator.
Synchronization panels
Connecting generators in parallel with each other and to the grid; load sharing.



More information
About OG Cells, Modular Cells, and Transfer Panels
These systems, also known as OG switchgear, medium-voltage switchgear, or modular switchgear, house circuit breakers, load breakers, disconnectors, grounding switches, current and voltage transformers, and protective relays all in one unit. Air-insulated (AIS) and gas-insulated (GIS) switchgear are selected based on site and operating conditions.
A transfer switch automatically transfers the load to the generator when the utility power is lost and back to the utility when power is restored. A synchronizing panel, on the other hand, ensures that multiple generators operate in parallel by matching their voltage, frequency, and phase angle, and shares the load according to their capacities.
- Medium-voltage switchgear and modular switchgear
- Cutting-type cell and load-separating cell
- Automatic Transfer Switch (ATS)
- Generator Synchronization Panel
Technical Approach
Design Coordinated with Conservation Efforts
In every OG project, short-circuit calculations, protection coordination, and interlocking logic are addressed together.
- Short-Circuit and Protection Coordination Calculations
- Selection and Settings of Digital Protection Relays
- Tests on cutting, disconnecting, and locking systems
- Protection Relay and Secondary Injection Tests
- Remote monitoring and SCADA integration
| Standard | IEC 62271 series |
|---|---|
| Cell types | Input, output, coupling, measurement, transformer protection |
| Switching | With a circuit breaker or load break switch |
| Protection | Digital protection relays |
| Monitoring | SCADA integration, remote monitoring |
| Cell markers | Astor Energy, Schneider Electric, and depending on the project |
| Tests | Mechanical and functional checks, relay tests, cable tests |
Process
From project to implementation
Discovery
Site survey and evaluation of the single-line diagram.
Project
OG project, calculations, and distribution company approval.
Supply
Supply of cells and protective equipment.
Installation
Cell, busbar, and OG cable installation.
Test
Relay, interlock, and cable tests.
Rejuvenation
Acceptance procedures and controlled energization.
Applications
At which facilities?
Frequently Asked Questions
Frequently Asked Questions
What is an OG cell?
It is a modular structure in which switchgear—which opens and closes, isolates, grounds, measures, and protects medium-voltage circuits—is housed within a metal enclosure.
What is the difference between a cell with a circuit breaker and one with a load break switch?
A circuit breaker can interrupt short-circuit currents. A load disconnect switch can turn normal load current on and off, but it is used in conjunction with a fuse for short-circuit protection.
Do you perform generator synchronization?
Yes. We offer parallel connection of generators to each other and to the grid, load sharing, and automatic transfer systems.
Related content
Information Center
Medium Voltage Project Design What Does "Synchronized" Mean? What Is Secondary Protection? What Is a Switching Yard?Request a quote for OG cells
Share your single-line diagram; we'll get back to you with the cell configuration and a quote.